53 resultados para aberrations, peripheral refraction, ocular aberrations, peripheral aberrations, Hartmann-Shack aberrometry, orthokeratology, intraocular lens implantation, corneal refractive surgery

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. This non-dispensing cross-over study was conducted to determine if lenses presoaked in Opti-Free RepleniSH (OFR) or ReNu MultiPlus (RMP) cause solution-induced corneal staining (SICS) and subsequent cell sloughing before the typical 2 h in vivo examination point.

Methods. Study lenses (PureVision) were worn bilaterally by 13 participants for periods of 15, 30, 60, and 120 min using two different contralateral care regimen pairings. The lens worn on the test eye was soaked overnight in either OFR or RMP and the control eye in Clear Care (CC). After lens removal, corneal staining was rated on a scale of 0 (negligible) to 100 (severe) for four peripheral quadrants and the central region, and the differential global staining score was calculated by subtracting baseline staining scores. Following the staining assessment, corneal cells were collected from the ocular surface using a non-contact irrigation system to determine ocular cell shedding rates.

Results. Differential global staining score with OFR was greater than CC with the differences being statistically significant at 30 and 60 min (p < 0.01). Maximum staining with RMP was significantly greater than OFR and peaked after 60 and 120 min of lens wear (p < 0.01). On average, 710 ± 470 ocular cells were collected after lens wear, with similar shedding seen independent of solution or lens wear duration (p > 0.05).

Conclusions. SICS occurred earlier but to a significantly lower degree when PureVision lenses were presoaked in OFR compared with RMP, while lenses presoaked in CC did not cause SICS. Ocular surface cell shedding after lens removal was not impacted by lens wear durations of <=2 h.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To measure in vivo and objectively the monochromatic aberrations at different wavelengths, and the chromatic difference of focus between green and infrared wavelengths in eyes implanted with two models of intraocular lenses (IOL).


Methods. Eighteen eyes participated in this study: nine implanted with Tecnis ZB99 1-Piece acrylic IOL and nine implanted with AcrySof SN60WF IOL. A custom-developed laser ray tracing (LRT) aberrometer was used to measure the optical aberrations, at 532 nm and 785 nm wavelengths. The monochromatic wave aberrations were described using a fifth-order Zernike polynomial expansion. The chromatic difference of focus was estimated as the difference between the equivalent spherical errors corresponding to each wavelength.


Results. Wave aberration measurements were highly reproducible. Except for the defocus term, no significant differences in high order aberrations (HOA) were found between wavelengths. The average chromatic difference of focus was 0.46 ± 0.15 diopters (D) in the Tecnis group, and 0.75 ± 0.12 D in the AcrySof group, and the difference was statistically significant (P < 0.05). Chromatic difference of focus in the AcrySof group was not statistically significantly different from the Longitudinal chromatic aberration (LCA) previously reported in a phakic population (0.78 ± 0.16 D). The impact of LCA on retinal image quality (measured in terms of Strehl ratio) was drastically reduced when considering HOA and astigmatism in comparison with a diffraction-limited eye, yielding the differences in retinal image quality between Tecnis and AcrySof IOLs not significant.


Conclusions. LRT aberrometry at different wavelengths is a reproducible technique to evaluate the chromatic difference of focus objectively in eyes implanted with IOLs. Replacement of the crystalline lens by the IOL did not increase chromatic difference of focus above that of phakic eyes in any of the groups. The AcrySof group showed chromatic difference of focus values very similar to physiological values in young eyes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the compatibility of a new silicone hydrogel lens, asmofilcon A (with four multipurpose disinfecting solutions: OPTIFREE RepleniSH, ReNu MultiPlus, Solo-Care Aqua and MeniCare Soft). Ocular responses and subjective responses were monitored with each lens-care system combination.

Methods: The study was conducted as a prospective, bilateral, clinical trial with a single-masked investigator, and randomized cross-over design with four phases, (one for each care system). Each study phase comprised of two consecutive days of lens wear where the lenses were inserted on day 1 directly from the blister-packs and worn for over 8 hr, then inserted on day 2 after overnight disinfection with one of the study lens care systems. Twenty-five adapted soft contact lens wearers who were able to wear their habitual lenses comfortably for more than 12 hr were recruited.

Results: There were statistically significant differences in corneal staining found for all the lens-care systems when comparing the results of day 1 (from the blister pack) with day 2 (following care system use) (P < 0.05). ReNu MultiPlus solution had the highest grade for corneal staining at the 2-hr time point on day 2 which then decreased by 6 hr (P < 0.05). There was no difference between the lens care systems and the rating of subjective comfort over either of the two days. The rating of dryness and burning sensations were only slightly increased at 6 hr for all lens care systems except ReNu MultiPlus where burning was highest on insertion (P < 0.05).

Conclusion: Corneal staining observed in this study does not seem to have been related to the presence of polyhexamethylene biguanide (0.0001% wv) that was present in three of the four care systems. Only one care system (ReNu MultiPlus) demonstrated an associated level of corneal staining that was statistically significant; however, this was not considered to be of clinical relevance. These results suggest that using this novel surface-treated silicone hydrogel lens may result in less lens and lens care-related interactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot study was conducted to evaluate human corneal epithelial cell shedding in response to wearing a silicone hydrogel contact lens/solution combination inducing corneal staining. The nature of ex vivo collected cells staining with fluorescein was also examined. A contralateral eye study was conducted in which up to eight participants were unilaterally exposed to a multipurpose contact lens solution/silicone hydrogel lens combination previously shown to induce corneal staining (renu® fresh™ and balafilcon A; test eye), with the other eye using a combination of balafilcon A soaked in a hydrogen peroxide care system (Clear Care®; control eye). Lenses were worn for 2, 4 or 6 hours. Corneal staining was graded after lens removal. The Ocular Surface Cell Collection Apparatus was used to collect cells from the cornea and the contact lens. In the test eye, maximum solution-induced corneal staining (SICS) was observed after 2 hours of lens wear (reducing significantly by 4 hours; p < 0.001). There were significantly more cells collected from the test eye after 4 hours of lens wear when compared to the control eye and the collection from the test eye after 2 hours (for both; n = 5; p < 0.001). The total cell yield at 4 hours was 813 ± 333 and 455 ± 218 for the test and control eyes, respectively (N = 5, triplicate, p = 0.003). A number of cells were observed to have taken up the fluorescein dye from the initial fluorescein instillation. Confocal microscopy of fluorescein-stained cells revealed that fluorescein was present throughout the cell cytoplasm and was retained in the cells for many hours after recovery from the corneal surface. This pilot study indicates that increased epithelial cell shedding was associated with a lens-solution combination which induces SICS. Our data provides insight into the transient nature of the SICS reaction and the nature of fluorescein staining observed in SICS.

Relevância:

60.00% 60.00%

Publicador: